Title
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
Rotary Switch
Display Symbols
Measurement Operation
A. AC Voltage Measurement
B. DC Current Measurement
C. Square Wave Output
D. Battery Test
E. Diodes Test
F. Measuring Resistance
G. DC Voltage Measurement
Table of Contents (1)
1
Model UT20B: OPERATING MANUAL
Vista de pagina 0
1 2 3 4 5 6 ... 33 34

Indice de contenidos

Pagina 1 - Table of Contents (1)

Page3456910101111131516171921TitleOverviewUnpacking InspectionSafety InformationRules For Safe OperationInternational Electrical SymbolsRotary SwitchD

Pagina 2 - Table of Contents (2)

Below table indicated for information about the rotary switch positions.Rotary SwitchRotary Switch PositionOFFVAΩVFunctionTurn on or off the power.AC

Pagina 3 - Overview

Measurement Operation (1)A. AC Voltage MeasurementWarningTo avoid harms to you or damages to the Meter from electric shock, pleasedo not attempt to m

Pagina 4 - Unpacking Inspection

Measurement Operation (2)Notel If the value of voltage to be measured is unknown, use the maximum measurement position (300V) and reduce the ran

Pagina 5 - Safety Information

Measurement Operation (3)B. DC Current MeasurementWarningNever attempt an in-circuit current measurement where the open-circuit voltagebetween the ci

Pagina 6 - Rules For Safe Operation (1)

Measurement Operation (4)3. Break the current path to be tested. Connect the red test lead to the morepositive side of the break and the black test le

Pagina 7 - Rules For Safe Operation (2)

Measurement Operation (5)C. Square Wave OutputWarningTo avoid damages to the Meter, do not allow output terminals to reach higherthan 10V.To measure

Pagina 8 - Rules For Safe Operation (3)

Measurement Operation (6)D. Battery TestTo test the battery proceed as follows:1. Set the rotary switch to the 1.5V or 9V measurement position in ra

Pagina 9

E. Diodes TestWarningTo avoid damages to the Meter or to the devices under test, disconnect circuitpower and discharge all the high-voltage capacitors

Pagina 10 - Display Symbols

2. For forward voltage drop readings on any semiconductor component, place thered test lead on the component’s anode and place the black test lead on

Pagina 11 - Measurement Operation (1)

F. Measuring ResistanceWarningTo avoid damages to the Meter or to the devices under test, disconnect circuitpower and discharge all the high-voltage

Pagina 12 - Measurement Operation (2)

Page23242425252626272728283031Table of Contents (2)TitleGeneral SpecificationsAccuracy SpecificationsA. AC VoltageB. DC CurrentC. Square Wave OutputD.

Pagina 13 - Measurement Operation (3)

Notel If the value of resistance to be measured is unknown, use the maximummeasurement position (2000kΩ) and reduce the range step by step until asati

Pagina 14 - Measurement Operation (4)

l The LCD displays " " indicating open-circuit for the tested resistor or the resistorvalue is higher than the maximum range of the Meter.

Pagina 15 - Measurement Operation (5)

2. Connect the test leads across with the object being measured.The measured value shows on the display.Notel If the value of voltage to be measured i

Pagina 16 - Measurement Operation (6)

l Maximum Voltage between anyTerminals and GroundinglFused Protection Input Terminall Maximum Displayl Measurement Speedl Temperaturel Relative Humidi

Pagina 17 - Measurement Operation (7)

Accuracy Specifications (1)Accuracy: (a% reading + b digits), guarantee for 1 year.Operating temperature: 23oC 5oC.Relative humidity: <75%.Temper

Pagina 18 - Measurement Operation (8)

Accuracy Specifications (2)C. Square Wave OutputRangeRemarkOutput approx. at 50Hz square wave. As a simple signalsource with 47kΩ resistance output.B

Pagina 19 - Measurement Operation (9)

Accuracy Specifications (3)E. Diodes TestD. Battery TestRange1.5V9VInternal Resistance30Ω1.8kΩOverload ProtectionMaximum current: 50mA.Maximum curre

Pagina 20 - Measurement Operation (10)

Accuracy Specifications (4)G. DC VoltageRange200mV2000mV20V200V300VResolution0.1mV1mV10mV100mV1VOverload Protection300V DC or AC rmsAccuracy(1.5%+2)(

Pagina 21 - Measurement Operation (11)

Maintenance (1)This section provides basic maintenance information including battery and fusereplacement instruction.WarningDo not attempt to repair o

Pagina 22 - Measurement Operation (12)

l Turn the Meter to OFF position when it is not in use and take out the batterywhen not using for a long time.l Do not store the Meter in a place of h

Pagina 23 - General Specifications

This Operation Manual covers information on safety and cautions. Please read therelevant information carefully and observe all the Warnings and Notes

Pagina 24 - Accuracy Specifications (1)

Maintenance (3)B. Replacing the BatteryWarningTo avoid false readings, which could lead to possible electric shock or personalinjury, replace the batt

Pagina 25 - Accuracy Specifications (2)

Maintenance (4)C. Replacing the FusesWarningTo avoid electrical shock or arc blast, or personal injury or damage to theMeter, use specified fuses ONLY

Pagina 26 - Accuracy Specifications (3)

Maintenance (5)~ END ~This operating manual is subject to change without notice.5. Rejoin the case bottom and case top,and reinstall the screw .Replac

Pagina 27 - Accuracy Specifications (4)

33Model UT20B: OPERATING MANUAL

Pagina 28 - Maintenance (1)

Manufacturer: UNI-TREND TECHNOLOGY(DONG GUAN)LIMITEDAddress: Dong Fang Da Dao, Bei Shan Dong Fang Industrial Development District, Hu Me

Pagina 29 - Maintenance (2)

Open the packing case and take out the Meter. Check the following items carefullyto see any missing or damaged part:In the event you find any missing

Pagina 30 - Maintenance (3)

This Meter complies with the standards IEC61010: in pollution degree 2, overvoltagecategory (CAT. II 300V) and double insulation.CAT. II: Local level,

Pagina 31 - Maintenance (4)

WarningTo avoid possible electric shock or personal injury, and to avoid possibledamage to the Meter or to the equipment under test, adhere to the fol

Pagina 32 - Maintenance (5)

Rules For Safe Operation (2)l When the Meter working at an effective voltage over 60V in DC or 30V rmsin AC, special care should be taken for there is

Pagina 33 - Model UT20B: OPERATING MANUAL

Rules For Safe Operation (3)electrical specifications replacement parts.l The internal circuit of the Meter shall not be altered at will to avoid dama

Pagina 34 - All rights reserved

International Electrical SymbolsAC (Alternating Current)DC (Direct Current)Grounding.Double Insulated.Deficiency of Built-In Battery.Diode.Fuse.Warnin

Comentarios a estos manuales

Sin comentarios