Uni-Trend UT10A Especificaciones

Busca en linea o descarga Especificaciones para Multímetros Uni-Trend UT10A. Uni-Trend UT10A multimeter Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 38
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Table of Contents (1)
Table of Contents
Title Page
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The Meter Structure
Functional Buttons
Measurement Operation
A. DC Voltage Measurement
B. AC Voltage Measurement
C. Measuring Resistance
D. Frequency and Duty Cycle Measurement
E. Measuring Diodes & Continuity
F. Capacitance Measurement
3
4
5
6
9
10
11
12
13
15
16
19
20
23
1
Model UT10A: OPERATING MANUAL
Vista de pagina 0
1 2 3 4 5 6 ... 37 38

Indice de contenidos

Pagina 1 - Table of Contents (1)

Table of Contents (1)Table of ContentsTitle PageOverviewUnpacking InspectionSafety Informa

Pagina 2 - Table of Contents (2)

The Meter StructureThe Meter Structure (see figure 1)1. LCD Display2. SELECT Button3. RELATIVE Mode Button4. DATA HOLD Button5. Hz/DUTY Button6. Rotar

Pagina 3 - Overview

Functional ButtonsFunctional ButtonsBelow table indicated for information about the functional button operationsButton Operation Perfo

Pagina 4 - Unpacking Inspection

Measurement Operation(1)Measurement OperationMake sure the Sleep Mode is not on if you found there is no display on the LCDafter turning on the Meter.

Pagina 5 - Safety Information

Measurement Operation(2)A. DC Voltage Measurement (see figure 2)( figure 2)Red Black13Model UT10A: OPERATING MANUAL

Pagina 6 - Rules For Safe Operation

Measurement Operation (3)To measure DC voltage, connect the Meter as follows:1. Set the rotary switch to DCV range.2. Connect the test leads acro

Pagina 7 - Rules For Safe Operation (2)

Measurement Operation (4)B. AC Voltage Measurement (see figure 2 with dotted line)WarningTo avoid harms to you or damages to the Meter from electric s

Pagina 8 - Rules For Safe Operation (3)

Measurement Operation (5)C. Measuring Resistance (see figure 3)( figure 3)Red BlackHz/Duty16Model UT10A: OPERATING MANUAL

Pagina 9

Measurement Operation(6)WarningTo avoid damages to the Meter or to the devices under test, disconnect circuitpower and discharge all the high-voltage

Pagina 10 - ( figure 1)

For high resistance (>1MΩ), it is normal taking several seconds to obtain a stablereading.When there is no input, for example in open circuit condi

Pagina 11 - Functional Buttons

D. Frequency and Duty Cycle Measurement (see figure 3 with dotted line)WarningTo avoid harm to you or damages to the Meter, do not attempt to measurev

Pagina 12 - Measurement Operation

Table of Contents (2)Title PageSleep ModeGeneral SpecificationsAccuracy Specifications

Pagina 13 - Measurement Operation(2)

E. Measuring Diodes & Continuity (see figure 3 with dotted line)WarningTo avoid damage to the Meter or to the equipment under test, disconnectcirc

Pagina 14 - Measurement Operation (3)

NoteIn a circuit, a good diode should still produce a forward voltage drop reading of0.5V to 0.8V; however; the reverse voltage drop reading can vary

Pagina 15 - Measurement Operation (4)

NoteWhen continuity testing has been completed, disconnect the connection betweenthe testing leads and the circuit under test.Measurement Operation(11

Pagina 16 - Measurement Operation (5)

F. Capacitance Measurement (see figure 3 with dotted line)WarningTo avoid damage to the Meter or to the equipment under test, disconnect thetested cir

Pagina 17 - Measurement Operation(6)

NoteFor testing the capacitor with polarity, connect the red test lead to anode & blacktest lead to cathodeFor measuring capacitance higher than 1

Pagina 18 - Measurement Operation(7)

Sleep ModeSleep Mode25Model UT10A: OPERATING MANUALTo preserve battery life, the Meter automatically turns off if you do not turn the rotaryswitch or

Pagina 19 - Measurement Operation(8)

General SpecificationsMaximum voltage between any Terminals and Grounding: 300V rms or 300DCVRange: Auto ranging.Maximum Display: 3999. (3 3/4 digit

Pagina 20 - Measurement Operation(9)

Accuracy Specifications(1)Accuracy Specifications27Model UT10A: OPERATING MANUALAccuracy: (a% reading + b digits), guarantee for 1 year.Operating tem

Pagina 21 - Measurement Operation(10)

A. DC VoltageRange Resolution Accuracy Overload Protection RemarksInput Impedance: 10MΩ400mV4V40V300V0.1mV1mV10mV100mV(0.8%+3)(0.8%+1)300V DC300V AC.

Pagina 22 - Measurement Operation(11)

Range Resolution Accuracy Overload Protection RemarksInput Impedance: 10MΩ.Frequency response:40Hz~400Hz.Display effective value ofsine wave (mean val

Pagina 23 - Measurement Operation(12)

OverviewOverviewWarningTo avoid electric shock or personal injury, read the “Safety Information” and“Rules for Safety Operation” carefully before usin

Pagina 24 - Measurement Operation(13)

Range Resolution Accuracy Overload Protection RemarksOpen circuit voltage:approx. 0.45V400Ω4kΩ40kΩ400kΩ4MΩ40MΩ0.1Ω1Ω10Ω100Ω1kΩ10kΩ(1.2%+2)(1%+2)250V A

Pagina 25 - Sleep Mode

Range Resolution Accuracy Overload Protection RemarksThe inputted voltageis sine waveWhen 10Hz ~10kHz: 1V rmsWhen 10kHz~100kHz:

Pagina 26 - General Specifications

Range Resolution Overload Protection RemarksPress Hz/DUTY button at ACV orDCV range to select Duty Cyclemeasurement mode.Reading is only for

Pagina 27 - Accuracy Specifications

Range Resolution Accuracy Overload Protection RemarksReading is only for reference4nF40nF400nF4µF40µF200µF0.001nF0.01nF0.1nF0.001µF0.01µF0.1µF(4%+3)25

Pagina 28 - Accuracy Specifications(2)

Maintenance(1)MaintenanceWarningDo not attempt to repair or service your Meter unless you are qualified to doso and have the relevant calibration, per

Pagina 29 - Accuracy Specifications(3)

Maintenance(2)A. General ServicePeriodically wipe the case with damp cloth and mild detergent. Do not usechemical solvent.To clean the terminals with

Pagina 30 - Accuracy Specifications(4)

Maintenance(3)B. Replacing the Battery (see figure 4)(figure 4)SCREW36Model UT10A: OPERATING MANUAL

Pagina 31 - Accuracy Specifications(5)

Maintenance(4)WarningTo avoid false readings, which could lead to possible electric shock or personalinjury, replace the battery as soon as the batter

Pagina 32 - Accuracy Specifications(6)

Copyright 2004 Uni-Trend International Limited.All rights reserved.Manufacturer: UNI-TREND TECHNOLOGY(DONG GUAN)LIMITEDAddress: Dong Fang Da Dao, B

Pagina 33 - Accuracy Specifications(7)

Unpacking InspectionUnpacking InspectionOpen the package case and take out the Meter. Check the following items carefullyto see any missing or damage

Pagina 34 - Maintenance

Safety InformationSafety InformationThis Meter complies with the standards IEC61010: in pollution degree 2, overvoltagecategory (CAT. II 300V) and dou

Pagina 35 - Maintenance(2)

Rules For Safe Operation (1)Rules For Safe OperationWarningTo avoid possible electric shock or personal injury, and to avoid possibledamage to the Met

Pagina 36 - Maintenance(3)

Rules For Safe Operation (2)7Model UT10A: OPERATING MANUALWhen the Meter working at an effective voltage over 60V in DC or 30V rmsin AC, special care

Pagina 37 - appears

Rules For Safe Operation (3)When servicing the Meter, use only the same model number or identicalelectrical specifications replacement parts.The inter

Pagina 38 - Model UT10A: OPERATING MANUAL

International Electrical SymbolsInternational Electrical SymbolsDeficiency of Built-In BatteryAC (Alternating Current)CapacitanceDouble InsulatedWarni

Comentarios a estos manuales

Sin comentarios