Model UT207/208OPERATING MANUAL

Pagina 2

Replace the battery as soon as the battery indicator appears. With alow battery, the Meter might produce false readings that can lead to electrics

Pagina 3

International Electrical SymbolsAC (Alternating Current)DC (Direct Current)AC or DCGroundingDouble InsulatedWarning. Refer to the Operating ManualDefi

Pagina 4

Figure 1The Meter Structure (see figure 1)Hand Guards: to protect user’s handfrom touching the dangerous area.Trigger: press the lever to open thetra

Pagina 5 - Overview

Press SELECT button to select the alternate functions includingV , , %Hz, A and (UT208 only).Starts recording of maximum and minimum

Pagina 6 - Unpacking Inspection

Press HOLD button for 2 seconds when turning on the Meter todisplay full icon.Button Operation PerformedHOLDWhen the Meter is at %Hz, V

Pagina 7 - Safety Information

SELECT MAX/MINHOLDHzZERON/A%Hz66A1000A66A1000AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/ARotary SwitchPositionsVFunctional ButtonsThe Effectiveness of Funct

Pagina 8 - Rules For Safe Operation

Figure 2Display Symbols (see figure 2)Model UT207/208: OPERATING MANUAL15

Pagina 9

Number Symbol Meaning1234567891011INRUSHMINMAXZEROIndicator for Surge currentMinimum reading displayedMaximum reading displayedIndi

Pagina 10

Number Symbol Meaning12131415161718192021Sleep mode is onTest of diodeThe continuity buzzer is on: Ohm. The unit of resistance.k

Pagina 11

A. DC/AC Voltage Measurement (see figure 3)To avoid harms to you or damages to the Meter from eletric shock, do notattempt to measure voltages higher

Pagina 12

Table of ContentsTitle PageOverviewUnpacking InspectionSafety InformationRules For Safe OperationInternational Electrical SymbolsThe Meter StructureFu

Pagina 13 - Functional Buttons

The DC Voltage ranges are: 6.6V, 66V and 600VThe AC Voltage ranges are: 6.6V, 66V and 600VTo measure DC/AC voltages, connect the Meter as follows:In

Pagina 14

B. Measuring Resistance (see figure 4)To avoid damages to the Meter or to the devicesunder test, disconnect circuit power anddischarge all the high-vo

Pagina 15

Connect the test leads across with the object being measured.The measured value shows on the display.3.NoteTo obtain a more precise reading, you could

Pagina 16 - (see figure 2)

C. Testing Diodes (see figure 5)To avoid damages to the Meter or to the devicesunder test, disconnect circuit power anddischarge all the high-voltage

Pagina 17

Insert the red test lead into the V Hz terminal and black test lead into the COMterminal.Set the rotary switch to . Press SELECT to switch to measur

Pagina 18

D. Testing for Continuity (see figure 6)To avoid damages to the Meter or to the devicesunder test, disconnect circuit power anddischarge all the high-

Pagina 19 - Measurement Operation

a circuit under test is higher than 100 .NoteWhen continuity testing has been completed, disconnect the connection betweenthe testing leads and the ci

Pagina 20

E. Frequency Measurement (see figure 7)To avoid harms to you or damages to the Meterfrom eletric shock, do not attempt to measurevoltages higher than

Pagina 21

NoteWhen frequency measurement has been completed, disconnect the connectionbetween the testing leads and the circuit under test, and remove the testi

Pagina 22

F. Duty Cycle Measurement (see figure 8)To avoid harms to you or damages to the Meterfrom eletric shock, do not attempt to measurevoltages higher than

Pagina 23 - Figure 5

Title Page30323537383839404041424243444545 G. DC Current Measurement H. AC Current Measurement I. UT208 only: Temperature Measure

Pagina 24

NoteWhen duty cycle measurement has been completed, disconnect the connectionbetween the testing leads and the circuit under test, and remove the test

Pagina 25 - Red Black

G. DC Current Measurement (see figure 9)The measurement ranges of current are: 66A and 1000A .To measure current, do the following:Set the rotary sw

Pagina 26

NoteIf the Meter does not display 00.00 when it is at 66A range, press ZERO tozeroing. After zeroing, it allows 10 digits bouncing reading.When the

Pagina 27

H. AC Current Measurement (see figure 10)The measurement ranges of current are: 66.00A and 1000A .To measure AC current, do the following:Set the ro

Pagina 28

transformer jaw, otherwise it will casue deviation. The Meter can only measureone conductor at a time, to meausre more than one condutor at a time wi

Pagina 29

When current measurement has been completed, disconnect the connectionbetween the conductor under test and the jaw, and remove the conductor awayfrom

Pagina 30

I. UT208 only: Temperature Measurement (see figure 11)The temperature measurement range: -40 ~1000and -40 ~1832 .To measure temperature measurement, c

Pagina 31

When the Meter is at range, it beeps to remind user to insert temperatureprobe.The Meter automatically displays the room temperature when the tempe

Pagina 32

Sleep ModeTo preserve battery life, the Meter automatically turns off if you do not turn the rotaryswitch or press any button for around 15 minutes.Th

Pagina 33

SpecificationsA. General Specifications:Maximum Voltage between any Terminals and grounding: Refer to different rangeinput protection voltage.Display

Pagina 34

Title Page4748494950 I. AC Current J. Temperature (UT208 only)Maintenance A. General Service B. Replacing the BatteryModel

Pagina 35

Battery Life: typically 150 hours (alkaline battery)Dimensions: 285.3mm x 105mm x 44.5mmWeight: Approximate 533g (battery included)B. Environmental R

Pagina 36

Accurate SpecificationsAccuracy: (a% reading + b digits), guarantee for 1 year.Operating temperature: 23 5Relative humidity: 80%R.HTemperature co

Pagina 37

B. AC VoltageRange6.600V66.00V600.0VResolution1mV10mV100mVAccuracy (1.2%+5)Overload protection600V DC/ACRemarks:Input Impedance: 10MFrequency Response

Pagina 38 - Sleep Mode

C. ResistanceRange660.0Ω6.600kΩ66.00kΩ660.0kΩ6.600MΩ66.00MΩResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩAccuracy (1.2%+2) (1%+2) (1.2%+2) (1.5%+2)Overload protection

Pagina 39 - Specifications

E. Continuity TestRange Resolution0.1AccuracyAround 30Ω,thebuzzer beeps.(Open circuit voltageapprox. –1.2V)Overload protection250VACRemark:The buzzer

Pagina 40

F. FrequencyRange660.0Hz6.600kHz66.00kHz660.0kHz6.600MHz66.00MHzResolution0.1Hz0.001kHz0.01kHz0.1kHz0.001MHz0.01MHzAccuracy (0.1%+3)Overload protectio

Pagina 41 - Accurate Specifications

G. Duty CycleRange0.1%~99.9%Resolution0.1%AccuracyFor reference onlyOverload protection250VACH. DC CurrentRange66.00A1000AResolution0.01A1AAccuracy (2

Pagina 42

Remarks:If the reading is positive, the current direction is from bottom to up. See figure10, the front case face up while the bottom case face down.

Pagina 43

I. AC CurrentRange66.00A1000AResolution0.01A1AAccuracy (2%+40) (2%+8)Overload protection250VACFrequencyResponse50Hz ~ 60HzThe operating temperature mu

Pagina 44

Non sine wave must follow the below data to adjust:Peak factor: 1.4~2.0, add 1.0% on the stated accuracy.Peak factor: 2.0~2.5, add 2.5% on the stated

Pagina 45

OverviewThis Operating Manual covers information on safety and cautions. Please read therelevant information carefully and observe all the Warnings an

Pagina 46

This section provides basic maintenance information including battery replacementinstruction.Do not attempt to repair or service your Meter unless you

Pagina 47

B. Replacing the Battery (see figure 12)Figure 12To avoid false readings, which could leadto possible electric shock or personalinjury, replace the ba

Pagina 48

To replace the battery:1. Turn the Meter off and remove all the connections from the input terminals2. Turn the Meter’s front case down.3. Remove the

Pagina 49

* END *This operating manual is subject to change without notice.Model UT207/208: OPERATING MANUAL52

Pagina 50 - MAINTENANCE

Copyright 2007 Uni-Trend Group Limited.All rights reserved.Manufacturer:Uni-Trend Technology (Dongguan) LimitedDong Fang Da DaoBei Shan Dong Fang Indu

Pagina 51

Item Description Qty12345English Operating ManualTest LeadPoint Co

Pagina 52

Safety InformationThis Meter complies with the standards IEC61010-1; IEC61010-2-032: in pollutiondegree 2, overvoltage category (CAT. II 600V, CAT. II

Pagina 53

Rules For Safe OperationTo avoid possible electric shock or personal injury, and to avoid possibledamage to the Meter or to the equipment under test,

Pagina 54

from the input terminals of the Meter and turn the Meter power off.The rotary switch should be placed in the right position and no anychangeover of ra