Model UT60A: OPERATING MANUAL
1
E.
Frequency & Duty Cycle
Table of Contents
Title
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The Meter Structure
Rotary Switch
Functional Buttons
Display Symbols
Measurement Ranges
A. Selecting a Measurement Range
B. Manual Ranging and Autoranging
Measurement Operation
A. AC & DC Voltage Measurement
B. Measuring Continuity, Diodes &
Resistance
C. Capacitance Measurement
D. Frequency & Duty Cycle Measurement
E. DC or AC Current Measurement
The POWER Button
The BLUE Button
The Use of Relative Value Mode
Operation of Hold Mode
General Specifications
Accuracy Specifications
A. AC Voltage
B. DC Voltage
C. Continuity, Diodes & Resistance Test
D. Capacitance
G.
AC Current
F.
DC Current
Vista de pagina 0
1 2 3 4 5 6 ... 43 44

Indice de contenidos

Pagina 1 - Table of Contents

Page34568910111417171719192124262830303031323333333435353636Model UT60A: OPERATING MANUAL 1E.Frequency & Duty CycleTable of ContentsTitleOverview

Pagina 2

Model UT60A: OPERATING MANUAL 10

Pagina 3 - Overview

Model UT60A: OPERATING MANUAL 11

Pagina 4 - Unpacking Inspection

Model UT60A: OPERATING MANUAL 12

Pagina 5 - Safety Information

Model UT60A: OPERATING MANUAL 13

Pagina 6 - Rules For Safe Operation (1)

Display Symbols (1)Model UT60A: OPERATING MANUAL 141kMnFHzVAAC152 3 4 5 6 78910 14~16

Pagina 7 - Rules For Safe Operation (2)

Display Symbols (2)Model UT60A: OPERATING MANUAL 15

Pagina 8

Model UT60A: OPERATING MANUAL 16

Pagina 9 - The Meter Structure

Measurement Ranges (1)A measurement range determines the highest value theMeter can measure. Most Meter functions have morethan one range. See "

Pagina 10 - Model UT60A: OPERATING MANUAL

Measurement Ranges (2)To enter and exit the manual range mode:1. Press RANGE.The Meter enters the manual range mode and turns off.Each presses of RANG

Pagina 11

Measurement Operation (1)A. AC & DC Voltage MeasurementWarningTo avoid harms to you or damages to the Meter fromelectric shock, please do not atte

Pagina 12

MaintenanceA. General ServiceB. Testing the FusesC. Replacing the BatteryD. Replacing the FusesRS232C Serial PortA. RS232C Port CableB. Setting

Pagina 13

Measurement Operation (2)Notel In each range, the Meter has an input impedanceof 10M . This loading effect can cause measurementerrors in high impe

Pagina 14 - Display Symbols (1)

Measurement Operation (3)Notel In each range, the Meter has an input impedanceof 10M . This loading effect can cause measurementerrors in high impe

Pagina 15 - Display Symbols (2)

Measurement Operation (4)Notel The LCD displays indicating the circuit beingtested is open.l When continuity testing has been completed,disconnect th

Pagina 16

Measurement Operation (5)Notel In a circuit, a good diode should still produce aforward voltage drop reading of 0.5V to 0.8V;however, the reverse volt

Pagina 17 - Measurement Ranges (1)

(figure 8)Measurement Operation (6)3. Connect the test leads across with the object beingmeasured.The measured value shows on the display.Notel The te

Pagina 18 - Measurement Ranges (2)

Measurement Operation (7)WarningTo avoid damage to the Meter or to the equipmentunder test, disconnect circuit power and dischargeall high-voltage cap

Pagina 19 - Measurement Operation (1)

Frequency MeasurementThe measurement ranges are from 10Hz to 40MHz. Tomeasure frequency, connect the Meter as follows:1. Insert the red test lead int

Pagina 20 - Measurement Operation (2)

Measurement Operation (9)Range SignalRequirementFrequencyRange200mVµA200µAmA20mAA2A10Hz~1kHzl When Hz measurement has been completed,disconnect the c

Pagina 21 - Measurement Operation (3)

Measurement Operation (10)E. DC or AC Current Measurement (see figure 10)SelectorDCAC(figure 10)WarningNever attempt an in-circuit current measurement

Pagina 22 - Measurement Operation (4)

Measurement Operation (11)4. The Meter defaults to DC current measurementmode. To toggle between DC and AC currentmeasurement function, press BLUE bu

Pagina 23 - Measurement Operation (5)

OverviewThis Operating Manual covers information on safety andcautions. Please read the relevant information carefullyand observe all the Warnings and

Pagina 24 - Measurement Operation (6)

The POWER buttonThis is a self-lock switch use to turn on or off the powerof the Meter.The BLUE buttonIt uses for selecting the required measurement f

Pagina 25 - Measurement Operation (7)

Operation of Hold ModeWarningTo avoid possibility of electric shock, do not useHold mode to determine if circuits are without power.The Hold mode will

Pagina 26 - Measurement Operation (8)

General Specificationsl Maximum Voltagebetween any Terminalsand GroundinglFused Protectionfor AmA InputTerminal:1000V rms.:0.5A, 250V fast type Gl

Pagina 27 - Measurement Operation (9)

Accuracy Specifications (1)Accuracy: (a% reading + b digits) guarantee for 1 year.Operating temperature: 23oC5oC.Relative humidity: <75%.Temperatur

Pagina 28 - Measurement Operation (10)

Accuracy Specifications (2)C. Continuity, Diodes & Resistance TestRange Resolution Accuracy OverloadProtectionContinuity Test(400.0 )0.1

Pagina 29 - Measurement Operation (11)

Accuracy Specifications (3)D. CapacitanceResolutionOverloadProtection40nF 10pF400nF 100pF4 F 1nF40 F 10nF(3%+5)100 F 100nF (4%+5)600VpRange Accur

Pagina 30 - The BLUE button

Accuracy Specifications (4)F. DC CurrentRemark:l 4A & 10A Range:For continuous measurement 10 seconds andinterval time between 2 measurements grea

Pagina 31 - Operation of Hold Mode

Maintenance (1)This section provides basic maintenance informationincluding battery and fuse replacement instruction.WarningDo not attempt to repair o

Pagina 32 - General Specifications

Maintenance (2)To test the fuse:1. Set the rotary switch to and select bypressing BLUE button.2. Plug a test lead into the terminal HzV and to

Pagina 33 - Accuracy Specifications (1)

Maintenance (3)2. Remove the screw from the battery compartment,and separate the battery compartment from the casebottom.3. Remove the battery from th

Pagina 34 - Accuracy Specifications (2)

Unpacking InspectionOpen the package case and take out the Meter. Checkthe following items carefully to see any missing ordamaged part:Item12345Descr

Pagina 35 - Accuracy Specifications (3)

Maintenance (4)5. Install ONLY replacement fuses with the identicaltype and specification as follows and make sure thefuse is fixed firmly in the brac

Pagina 36 - Accuracy Specifications (4)

RS232C Serial Port (1)A. RS232C Port CableTheMeterComputerD-sub9 PinMaleD-sub9 PinFemaleD-sub25 PinFemalePinNameRemark22 3 RXReceivingData3 3 2

Pagina 37 - Maintenance (1)

RS232C Serial Port (2)C. System Requirements for Installing the UT60AInterface ProgramTo use UT60A Interface Program, you need the followinghardware a

Pagina 38 - Maintenance (2)

Model UT60A: OPERATING MANUAL43

Pagina 39 - Maintenance (3)

Manufacturer: UNI-TREND TECHNOLOGY(DONG GUAN)LIMITEDAddress: Dong Fang Da Dao, Bei Shan Dong Fang Industrial Development District, Hu Me

Pagina 40 - Maintenance (4)

Safety InformationThis Meter complies with the standards IEC61010: inpollution degree 2, overvoltage category (CAT. III 1000V,CAT. IV 600V) and double

Pagina 41 - RS232C Serial Port (1)

Rules For Safe Operation (1)WarningTo avoid possible electric shock or personal injury,and to avoid possible damage to the Meter or to theequipment un

Pagina 42 - RS232C Serial Port (2)

Rules For Safe Operation (2)l Before measuring current, check the Meter'sfuses and turn off power to the circuit beforeconnecting the Meter to th

Pagina 43

International Electrical SymbolsAC (Alternating Current).DC (Direct Current).AC or DC.Grounding.Double Insulated.Deficiency of Built-In Battery.Contin

Pagina 44

The Meter StructureModel UT60A: OPERATING MANUAL 9